Part Number Hot Search : 
28F00 58128 AN8031 PTC60 MM1ZB33H KBPC3 HER105 BZT11
Product Description
Full Text Search
 

To Download 232E Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 05060
232B
&
Only One Name Means ProT ek'TionTM
232E
INDUSTRIAL COMPUTER DA A LINE PROTECTOR T
APPLICA TIONS RS-232 Transmission Lines Catagory 3 Systems Control & Monitoring Systems Analog Signal Transmissions Telemetry Outstations IEC COMPA TIBILITY (EN61000-4) 61000-4-2 (ESD): Air - 15kV, Contact - 8kV 61000-4-4 (EFT): 40A - 5/50ns 61000-4-5 (Surge): 8/20s - 95A, Level 4 (Line-Gnd) & 48A, Level 4 (Line-Line) 232E FEA TURES
232B
4 WIRE LINE-GROUND PROTECTION Designed for EIA Standard RS-232 Data Lines Permanent Two-Stage, 2 Line Pair or 4 Line Protector Subnanosecond Response Time Automatic Reset - Does Not Interrupt Service Effective Against Lightning, Inductive Switching and ESD
MECHANICAL CHARACTERISTICS Weight: 232B - 28 grams & 232E - 142 grams (Approximate Flammability Rating UL 94V-0 Device Marking: Case - Logo, Terminal Designations & Part Number Board - Logo, Date Code & Part Number
DESCRIPTION The 232B/E is a two-stage transient voltage protector the provides primary and secondary protection against lightning, inductive switching and electrostatic discharge (ESD) transient threats. The first stage diverts the transient current through the ground terminal return path and the second stage clamps the voltage to a safe level without interruption of service. The 232B/E is designed to protect two line pairs or four (4) data lines from commonmode (line-to-ground) lightning or switching transients. The datalines are isolated to prevent near or far end cross talk problems. This product can also be used on data and transmission lines, security, timing and control interface circuits.
05060.R3 11/03
1
www.protekdevices.com
232B
&
232E
DEVICE CHARACTERISTICS MAXIMUM RATINGS @ 25C
Peak Operatiing Line Voltage (VOP) 25V 200mA Operating Line Current (IO) Maximum Transient Voltage Maximum Transient Current (8/20s waveform) Operating & Storage Temperature Response Time 10kV 10kA/Wire 40kA/Protector -55C to 100C < 1 nanosecond
ELECTRICAL CHARACTERISTICS @ 25C
MAXIMUM CLAMPING VOLTAGE (8/20s) @ 500A VC VOLTS 40 MAXIMUM LINE THRUPUT RESISTANCE R OHMS 12 MAXIMUM LEAKAGE CURRENT @ 25VOP ID A 5 MAXIMUM CAPACITANCE
@ 0V, 1MHz C pF 2000
INST ALLA TION INSTRUCTIONS
There are five (5) terminals on both the line and equipment side of the 232E - four data line terminals and two ground terminals. Both ground terminals, as shown on the label, are connected internally. A single ground connection is sufficient. However, it is recommended that both ground connections be used for a lower impedance path to earth. This connection can be made through the green AC power ground wire or a known earth ground. The ground wire should be #14 stranded wire. Incoming data lines are cut or disconnected from the equipment to insert the 232E product. The line side of the terminals are to be connected to data lines from the outside world or lines that carry the transient threats into the equipment to be protected. The equipment side of the terminals are to be connected to the equipment to be protected . The location of the product should be such that these wires are as short as possible. A #18 or 20 gauge wire can be used for these connections. Protectors should be installed at both ends of the data lines, at the point of entry to buildings. Use the shortest possible connection to a low impedance earth ground. Proper grounding and bonding are essential for computer installation applications. The 232B circuit board requires an edge connector interface for installation. The circuit board should be located at the building interface for incoming lines from the outside world. Both the 232B and 232E can be mounted on a data line circuit panel, which must be hard wired to the incoming data lines. Unprotected input lines and ground wires are to be separated from protected output lines to prevent electromagnetic coupling of noise from high transient currents on the input lines. ProTek's data line protector is designed with a short circuit failure mode to give maximum protection. A fuse, fussable link, or circuit breaker is recommended for each data/signal line on the input (line) side of the protector for those applications that require an open circuit failure mode. Caution: A low DC resistance ground may not be indicative of a good lightning ground. Lightning contains a broad spectrum of frequencies up to 1 MHz. A low impedance path to ground at the transient frequencies is necessary. A ground strap is recommended or a #6 AWG stranded wire. For wire lengths over 1.5 meters, there may be some excessive line to earth potential under severe thunderstorm conditions. For these applications, an additional protector may be necessary at the equipment interface.
05060.R3 11/03
2
www.protekdevices.com
232B
&
232E
PACKAGE OUTLINE & DIMENSIONS
232E Case Outline
3.8" MAX (95.5mm) 3.25"0.015" (82.6mm0.38mm) 3.0" MAX (76.2mm)
WARNING:
232B Board Outline
0.50" MAX (12.7mm)
3 EQUIPMENT
4
LINE
GND
LINE
1
1.125" (30.2mm)
2
4 3 GND 2 1
2.25" MAX (57.2mm)
EQUIPMENT
1.90" MAX (48.2mm)
Adhesive Mylar Label
Terminal Screw
Mounting Hole for #8 Screw
030" MAX (7.6mm) Orientation Notch
2 #6 Screws Terminal Strip 1.19" MAX (30.2mm) OUTPUT Connected to Transmit/Receive Circuits Note: I/O contacts spaced at 0.156" (3.96mm) centers.
5 GND
12
15
CONTINUITY INPUT OUTPUT 5 12 4 13 14 3 15 2 INPUT Connected to Line From Outside World
0.07" (17.8mm)
0.61" MAX (15.5mm)
COPYRIGHT (c) ProTek Devices 2003 SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC). DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer's and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products.
ProTek Devices 2929 South Fair Lane, Tempe, AZ 85282 Tel: 602-431-8101 Fax: 602-431-2288 E-Mail: sales@protekdevices.com Web Site: www.protekdevices.com
www.protekdevices.com
05060.R3 11/03
3


▲Up To Search▲   

 
Price & Availability of 232E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X